T6DCM-B38-B14-3L00-C1 Denison Double Vane Pump 240 bar
| Model Number | T6DCM B38 B14 3L00 C1 |
|---|
Product Description
Product Overview
The T6CC, T6DCM, and T6EDM Series, manufactured by Parker Denison, are renowned fixed-displacement vane pump product lines celebrated for their high-pressure capability, wide speed range, and compact design. The T6 Series encompasses three housing sizes—C, D, and E—each accommodating cartridge kits with different displacements. C-Series displacement ranges from 10.8 to 100.0 cm³/rev, D-Series from 47.6 to 158.0 cm³/rev, and E-Series from 132.3 to 227.1 cm³/rev.
The T6DCM combines D-housing and C-housing in a double configuration; T6CC combines two C-housings; T6EDM combines E-housing and D-housing. All T6 Series pumps feature a balanced-type fixed-displacement design, with fully balanced radial hydraulic forces ensuring long bearing life and smooth operation. The series utilizes Denison’s patented pin-vane (double-lip) technology, delivering higher operating pressure and greater flow within the same housing size. Double/triple pump configurations integrate multiple independent pumping sections into a single housing driven by one shaft, simultaneously powering multiple independent hydraulic circuits.
Our products are manufactured to be 100% interchangeable with Parker Denison original specifications—a true “drop-in” replacement solution. Every unit undergoes 100% full-load and flow-matching testing under simulated operating conditions before shipment, ensuring volumetric efficiency, flow rate, and noise performance meet or exceed original specifications at rated pressure.
Technical Specifications
T6DCM-B38-B14-3L00-C1 (Double Pump)
Product Type: Double Fixed Displacement Vane Pump
Brand: Parker Denison
Series: T6DCM (T6D Housing + T6C Housing Double Combination, Mobile)
Section 1 Displacement (Front, T6D, Cartridge B38): 120.3 ml/r
Section 2 Displacement (Rear, T6C, Cartridge B14): 46.0 ml/r
Total Displacement: 166.3 ml/r (120.3 + 46.0)
Rated Pressure (Section 1 / Section 2): 240 bar / 275 bar
Maximum Intermittent Pressure: 275 bar
Rated Speed Range: 600 – 2200 r/min
Maximum Speed: 2200 r/min
Mounting: SAE C 2-Bolt Flange (J744c)
Shaft Type: 3 = SAE C Splined Shaft (14 Teeth 12/24DP)
Rotation: L = Counter-clockwise (viewed from shaft end)
Port Position: 00
Seal Material: C1 = NBR Standard Seal
Fluid Compatibility: Mineral oils, water glycols, phosphate esters
Recommended Viscosity: ISO VG32, VG46, or VG68 anti-wear hydraulic oil
Recommended Fluid Cleanliness: NAS 9 or higher
T6DCM-B38-B25-3R13-C101 (Double Pump)
Product Type: Double Fixed Displacement Vane Pump
Brand: Parker Denison
Series: T6DCM (T6D Housing + T6C Housing Double Combination, Mobile)
Section 1 Displacement (Front, T6D, Cartridge B38): 120.3 ml/r
Section 2 Displacement (Rear, T6C, Cartridge B25): 79.3 ml/r
Total Displacement: 199.6 ml/r (120.3 + 79.3)
Rated Pressure (Section 1 / Section 2): 240 bar / 275 bar
Maximum Intermittent Pressure: 275 bar
Rated Speed Range: 600 – 2200 r/min
Maximum Speed: 2200 r/min
Mounting: SAE C 2-Bolt Flange (J744c)
Shaft Type: 3 = SAE C Splined Shaft (14 Teeth 12/24DP)
Rotation: R = Clockwise (viewed from shaft end)
Port Position: 13 (Specific port configuration)
Seal Material: C101 = NBR Seal
Fluid Compatibility: Mineral oils, water glycols, phosphate esters
Recommended Viscosity: ISO VG32, VG46, or VG68 anti-wear hydraulic oil
Recommended Fluid Cleanliness: NAS 9 or higher
T6CC Series (Double Pump)
Product Type: Double Fixed Displacement Vane Pump
Brand: Parker Denison
Series: T6CC (T6C Housing + T6C Housing Double Combination)
Displacement Range: 10.8 – 100.0 cm³/rev (total displacement depends on cartridge combination)
Rated Pressure: Up to 275 bar
Maximum Intermittent Pressure: 280–300 bar
Rated Speed Range: 600 – 2800 r/min
Maximum Speed: 2800 r/min
Mounting: SAE B or C 2-Bolt Flange
Shaft Type: Keyed or Splined (optional)
Rotation: R = Clockwise / L = Counter-clockwise (optional)
Seal Material: NBR Standard Seal
Net Weight: Approx. 16–43 kg (configuration-dependent)
Fluid Compatibility: Mineral oils, water glycols, phosphate esters
Recommended Viscosity: ISO VG32, VG46, or VG68 anti-wear hydraulic oil
Recommended Fluid Cleanliness: NAS 9 or higher
T6EDM Series (Double Pump)
Product Type: Double Fixed Displacement Vane Pump
Brand: Parker Denison
Series: T6EDM (T6E Housing + T6D Housing Double Combination, Mobile)
Displacement Range: 132.3 – 227.1 cm³/rev (E-Series) + 47.6 – 158.0 cm³/rev (D-Series)
Rated Pressure: Up to 240 bar
Maximum Intermittent Pressure: 275 bar
Rated Speed Range: 600 – 2200 r/min
Maximum Speed: 2200 r/min
Mounting: SAE C 2-Bolt Flange
Shaft Type: Keyed or Splined
Rotation: R = Clockwise / L = Counter-clockwise
Seal Material: NBR Standard Seal
Net Weight: Approx. 67 kg
Fluid Compatibility: Mineral oils, water glycols, phosphate esters
Recommended Viscosity: ISO VG32, VG46, or VG68 anti-wear hydraulic oil
Key Technical Advantages
1. Pin-Vane (Double-Lip) Patent Technology – Exceptional Contamination Resistance
The Denison T6 Series features a unique pin-vane (double-lip) structure design. Outlet pressure is continuously applied to the pin, providing a steady, light force against the vane. This design minimizes noise levels and improves volumetric efficiency while providing exceptional contamination resistance.
2. Balanced-Type Design – Extended Bearing Life
The T6 Series employs a balanced-type hydraulic design, fully balancing radial hydraulic forces and eliminating radial loads on the rotor. This dramatically reduces bearing stress, significantly extending bearing life. The balanced design compensates for wear and temperature changes, maintaining good lubrication between rotor and port plate even under high-viscosity or low-temperature conditions.
3. Wide Speed Range and Cold-Start Capability
The T6 Series supports a wide speed range of 400–2800 r/min. It operates reliably even at low speeds (600 rpm). The wide viscosity range of 2000–10 cSt permits cold starts and hot operation.
4. Cartridge Design for Rapid Maintenance
The T6 Series features cartridge-type construction, allowing individual pump cartridges (cam ring, rotor, vanes, plates) to be replaced quickly and independently. The “drop-in” assembly method simplifies modification and repair while minimizing contamination ingress risk. On-site repairs can be completed in minutes without removing the entire pump.
5. Exceptionally Low Noise and Low Pressure Ripple
The T6 Series achieves pressure ripple as low as ±2 bar, significantly reducing piping noise and protecting other components in the circuit. The wide speed range combined with large-displacement cartridges enables lowest noise operation within the smallest envelope.
6. Through-Drive Capability for Flexible System Expansion
The T6 Series supports multiple pump series connections. Double pumps offer 32 mounting configuration options—a single power source can drive multiple hydraulic pumps, greatly simplifying complex hydraulic system design and reducing installation costs.
7. 100% Drop-In Interchangeability – Zero Retrofit Cost
Manufactured to exact Parker Denison original specifications—mounting dimensions, port locations, and shaft configurations are identical to the original. Mounting complies with SAE J744c 2-bolt flange standards. No piping modifications or installation adapters are required for direct replacement.
Application Areas
Mobile Machinery: T6*M Series optimized for mobile applications
Injection Molding Machines: T6CC/T6DCM double pumps for high-pressure clamping and low-pressure injection/plasticizing dual-circuit systems
Die-Casting Machinery: Stable hydraulic power source for high-pressure metal forming
CNC Machine Tools & Machining Centers: High-pressure feed and low-pressure auxiliary dual-circuit precision hydraulic systems
Hydraulic Press Series: Four-column presses, shearing machines, bending machines, stamping presses
Construction Equipment: Excavators, loaders, forklifts, road compactors—multi-actuator dual-circuit systems
Agricultural Machinery: Combine harvesters, tractor hydraulic systems
Marine & Military Machinery: Marine equipment and military hydraulic systems
Industrial Power Units: Core power source for indoor hydraulic stations requiring high pressure and low noise
Expert Maintenance Tips
1. Model Identification and Selection
T6C Series Housing: Displacement range 10.8–100.0 cm³/rev, cartridge codes 003, 005, 006, 008, 010, 012, 014, 017, 020, 022, 025, 028, 031
T6D Series Housing: Displacement range 47.6–158.0 cm³/rev, cartridge codes 014, 017, 020, 024, 028, 031, 035, 038, 042, 045, 050
T6E Series Housing: Displacement range 132.3–227.1 cm³/rev
T6DCM Model: D-housing (Section 1) + C-housing (Section 2) double combination
T6CC Model: C-housing + C-housing double combination
T6EDM Model: E-housing (Section 1) + D-housing (Section 2) double combination
Seal Codes: C1/B1 = NBR standard seals for mineral oils; phosphate esters/water glycols require special seal models
2. Installation Precautions
Verify pump rotation direction matches system requirements—R denotes clockwise, L denotes counter-clockwise (viewed from shaft end).
Confirm shaft type matches—T6DCM 3L00/3R13 uses SAE C splined shaft (14 teeth 12/24DP).
Mounting complies with SAE J744c 2-bolt flange standards.
Suction piping should be as short as possible, minimizing unnecessary restrictions.
The pump housing must not bear piping loads; suction and discharge lines must have independent supports.
Coupling selection should minimize pump shaft load (weight, alignment).
3. Pre-Startup Checklist
Before startup, verify pump rotation, speed range, pressure, temperature, and fluid quality and viscosity.
Check pump inlet conditions meet application requirements.
Verify shaft type meets torque requirements.
Ensure filtration maintains fluid cleanliness.
Prime the pump by filling the housing with oil before first startup to prevent dry running.
4. Fluid Management
ISO VG32, VG46, or VG68 anti-wear hydraulic oil is recommended.
The T6 Series accommodates a wide viscosity range (2000–10 cSt), permitting cold starts and hot operation.
Compatible fire-resistant fluids include phosphate esters, chlorinated hydrocarbons, water glycols, and water-in-oil emulsions.
Fluid cleanliness should be maintained at NAS 9 or higher—contamination is the leading cause of premature vane pump failure.
Regularly check oil temperature to ensure it does not exceed 80°C.
5. Scheduled Maintenance
Replace hydraulic oil and filters every 2000 operating hours or annually.
The T6 Series features cartridge-type construction—cartridges can be replaced independently.
Cartridge replacement can be completed without removing the entire pump.
For mobile pumps, “C” and “D” series cartridges are bidirectional—identified by “B” in the model code. To change rotation, simply reposition the cam ring locating pin hole on the port plate.
Mounting bolts and flange connections may loosen due to vibration; inspect and tighten periodically.
Pump operating environment should avoid noise, contamination, and vibration sources where possible.


Company Profile


Frequently Asked Questions
1.What ls our Main Products?
1.Hydraulic pump
2.Hydraulic valve
3.Hydraulic motor
4.Hydraulic cylinder
5.Hydraulic parts
2. What about the MOQ?
3.What are your advantages?
- Adhere to quality first.
- Support customization, ODM & OEM service.
- 1-year warranty and complete after-sales support.
- Safe and fast shipping worldwide.
- 24-hour online service for your inquiries.
4.Are you a manufacturer? What’s your delivery time?
5.Which payment methods are accepted?
6.How will you deliver my goods?
7.How do you inspect and guarantee your products?
8.What about after-sales service?
9.What are your main applications?
- Hydraulic systems
- Agricultural machinery
- Construction machinery
- Automobile industry
- Local distributors and maintenance centers
10.Can I get a discount for bulk orders?
Professional Manufacturer