SV3-10-0-0-24DG Danfoss Vickers Solenoid Valve 210 Bar
| Model Number | SV3-10-0-0-24DG |
|---|
Product Description
Product Overview
The SV3-10-0-0-24DG, SV3-10-OP-0-24DG and SV3-10-0P-0-24DG belong to the Danfoss / Vickers SV3-10-O screw-in cartridge solenoid valve family.
Danfoss PowerSource identifies:
- SV3-10-0-0-24DG as SV3-10-O-0-24D-G
- SV3-10-OP-0-24DG as SV3-10-O-P-0-24D-G
The P configuration specifies a push-type manual override. The G configuration uses an ISO 4400 / DIN 43650 electrical connector, while 24D indicates 24 VDC operation.
The SV3-10-O is a 2-way, 2-position, normally open, poppet-type, pilot-operated screw-in cartridge solenoid valve. When de-energized, the valve permits bidirectional flow between ports 1 and 2. When energized, the pilot mechanism closes the relevant flow path, blocking flow from port 2 to port 1 while allowing port 1 to port 2 when the required pressure condition is established.
For OEM replacement and field service, the primary engineering considerations are C-10-2 cavity compatibility, 24 VDC electrical matching, DIN 43650 connector configuration, 45 L/min rated flow and 210 bar application pressure.
Our replacement process focuses on dimensional compatibility, electrical matching and functional validation, with 100% simulated operating-condition testing to support reliable interchangeability in hydraulic equipment.
Technical Specifications
SV3-10-0-0-24DG
- Brand: Danfoss / Vickers
- Official Model Code: SV3-10-O-0-24D-G
- Part Number: 02-200855
- Product Type: Screw-In Cartridge Solenoid Valve
- Valve Design: Poppet Type
- Function: 2-Way, 2-Position, Normally Open
- Actuation: Pilot Operated, Solenoid Actuated
- Cavity: C-10-2
- Rated Flow: 45 L/min (12 USgpm)
- Typical Application Pressure: 210 bar (3000 psi)
- Cartridge Fatigue Pressure: 210 bar (3000 psi)
- Internal Leakage: Less than 5 drops/min maximum at 210 bar
- Voltage: 24 VDC
- Connector: G — ISO 4400 / DIN 43650
- Seal Material: Buna-N
- Temperature Range: -40°C to +120°C
- Fluid Compatibility: General-purpose hydraulic fluids such as MIL-H-5606, SAE 10 and SAE 20
- Recommended Filtration: Cleanliness code 18/16/13
- Standard Housing Material: Aluminum when used with standard housing
- Approximate Dimensions: 101.6 mm length × 38.86 mm width × 49.02 mm height
- Weight: approximately 0.4 kg including coil
- Pump Displacement: N/A
- Maximum Shaft Speed: N/A
- Control Method: On/off electromagnetic control
Danfoss directly confirms the exact model configuration and key product characteristics, while the Vickers technical catalogue defines the performance data for the SV3-10-O series.
SV3-10-OP-0-24DG
- Brand: Danfoss / Vickers
- Official Model Code: SV3-10-O-P-0-24D-G
- Part Number: 02-181629
- Product Type: Screw-In Cartridge Solenoid Valve
- Valve Design: Poppet Type
- Function: 2-Way, 2-Position, Normally Open
- Actuation: Pilot Operated, Solenoid Actuated
- Manual Override: P — Push Type
- Cavity: C-10-2
- Rated Flow: 45 L/min (12 USgpm)
- Typical Application Pressure: 210 bar (3000 psi)
- Cartridge Fatigue Pressure: 210 bar (3000 psi)
- Internal Leakage: Less than 5 drops/min maximum at 210 bar
- Voltage: 24 VDC
- Connector: G — ISO 4400 / DIN 43650
- Seal Material: Buna-N
- Temperature Range: -40°C to +120°C
- Filtration: Cleanliness code 18/16/13
- Dimensions: approximately 133.86 mm height × 63.5 mm length × 50.8 mm width according to the current Danfoss product record
- Control Method: Pilot-operated electromagnetic on/off control with push manual override
- Pump Displacement: N/A
- Maximum Shaft Speed: N/A
Danfoss PowerSource directly identifies 02-181629 as SV3-10-O-P-0-24D-G, while the Vickers model-code documentation specifies P as the push-type manual override option.
SV3-10-0P-0-24DG
- Common Market Model: SV3-10-0P-0-24DG
- Standardized Danfoss Model Code: SV3-10-O-P-0-24D-G
- Danfoss Part Number: 02-181629
- Product Type: Screw-In Cartridge Solenoid Valve
- Valve Design: Poppet Type
- Function: 2-Way, 2-Position, Normally Open
- Manual Override: Push Type
- Cavity: C-10-2
- Voltage: 24 VDC
- Connector: ISO 4400 / DIN 43650
- Rated Flow: 45 L/min (12 USgpm)
- Typical Application Pressure: 210 bar (3000 psi)
- Cartridge Fatigue Pressure: 210 bar (3000 psi)
- Internal Leakage: Less than 5 drops/min maximum at 210 bar
- Temperature Range: -40°C to +120°C
- Seal Material: Buna-N
- Recommended Filtration: 18/16/13
- Pump Displacement: N/A
- Maximum Shaft Speed: N/A
- Control Method: Pilot-operated electromagnetic control with push-type manual override
SV3-10-0P-0-24DG and SV3-10-OP-0-24DG refer to the same standardized Danfoss configuration, 02-181629 / SV3-10-O-P-0-24D-G. They should therefore not be represented as two different hydraulic functions on the same technical specification database.
Key Technical Advantages
1. Poppet Design for Controlled Leakage
The SV3-10-O uses a poppet architecture with a specified internal leakage limit of less than 5 drops/min at 210 bar. This makes the design appropriate for hydraulic circuits where control of internal leakage is important.
2. Pilot-Operated Hydraulic Control
The valve uses pilot operation rather than relying solely on direct mechanical movement of the main hydraulic element. This allows a compact cartridge package to manage the specified 45 L/min flow capacity.
Because it is pilot operated, however, the valve is sensitive to operating flow conditions. The technical documentation notes that the valve requires a certain minimum flow for shifting, which should be considered in very-low-flow applications.
3. 45 L/min Capacity in a C-10-2 Cartridge Platform
The SV3-10-O series provides 45 L/min (12 USgpm) rated flow within the C-10-2 screw-in cartridge platform, making it suitable for manifold-integrated hydraulic control architectures.
4. Hardened and Ground Working Parts
The Vickers/Eaton technical literature specifies hardened and ground working parts and a lapped seat for this valve family. These manufacturing features contribute to wear resistance, controlled clearances and repeatable sealing performance.
5. Standard 24 VDC DIN Connector
The specified configuration uses 24 VDC electrical actuation and an ISO 4400 / DIN 43650 connector. Standardized electrical interfaces simplify OEM wiring and field maintenance.
6. Push Manual Override Option
The SV3-10-OP-0-24DG / SV3-10-0P-0-24DG versions incorporate a push-type manual override. This feature is useful during commissioning, troubleshooting and electrical fault diagnosis when manual valve actuation is required.
7. OEM Replacement and Interchangeability
For replacement applications, the critical matching points include:
- C-10-2 cavity compatibility
- 24 VDC electrical configuration
- ISO 4400 / DIN 43650 connector
- Normally-open operating logic
- Cartridge installation geometry
- Seal compatibility
Our replacement process emphasizes interchangeability verification and 100% simulated operating-condition testing before delivery.
Application Areas
Typical applications include:
- Agricultural harvesters
- Refuse haulers
- Mobile hydraulic equipment
- Industrial hydraulic systems
- Hydraulic manifolds
- Cartridge valve blocks
- Hydraulic dump circuits
- Diverter circuits
- Load-holding related control circuits
- OEM hydraulic valve replacement
Danfoss PowerSource application information for the SV3-10 family includes harvesters, refuse haulers, mobile and industrial applications.
Expert Maintenance Tips
Verify the Cavity Before Installation
The SV3-10 series uses a C-10-2 cavity. Always verify the manifold cavity geometry and sealing surfaces before installing a replacement cartridge.
Use the Correct Installation Torque
The Vickers technical documentation gives an installation torque of 47–54 Nm for the cartridge in the specified aluminum housing configuration. Excessive torque can damage the valve and affect proper operation.
Maintain Hydraulic Cleanliness
The specified recommended cleanliness level is 18/16/13. Contamination can interfere with the pilot mechanism, poppet and lapped sealing surfaces and may cause incomplete shifting or leakage.
Consider Minimum Flow Conditions
Since SV3-10-O is pilot operated, the hydraulic circuit must provide appropriate flow conditions for reliable shifting. Very-low-flow circuits should be evaluated separately before selecting this valve architecture.
Verify the Actual 24 VDC Supply
Measure voltage at the valve connector under load and check wiring, connectors and controller output. A voltage drop can reduce solenoid force and create symptoms that may be mistaken for a mechanical valve fault.
Release the Manual Override After Testing
For OP / 0P versions, make sure the push-type manual override is fully released after commissioning or troubleshooting so that it does not interfere with normal solenoid operation.



Complete List of SV Series Models (Common Basic models, Excluding suffixes)
SV3-06-0-0, SV3-10-0-0, SV3-16-0-0, SV3-20-0-0, SV3-25-0-0
SV4 Series (Medium Flow)
SV4-32-0-0, SV4-40-0-0, SV4-50-0-0, SV4-63-0-0
SV5 Series (Medium and High traffic)
SV5-80-0-0, SV5-100-0-0, SV5-125-0-0
Derivative models of electromagnetic specifications (examples)
SV3-10-0-0-24DG, SV3-10-0-0-230AG, SV3-10-0-2-2G-12DG, SV3-10-CM-0-24DG
Company Profile


Frequently Asked Questions
1.What ls our Main Products?
1.Hydraulic pump
2.Hydraulic valve
3.Hydraulic motor
4.Hydraulic cylinder
5.Hydraulic parts
2. What about the MOQ?
3.What are your advantages?
- Adhere to quality first.
- Support customization, ODM & OEM service.
- 1-year warranty and complete after-sales support.
- Safe and fast shipping worldwide.
- 24-hour online service for your inquiries.
4.Are you a manufacturer? What’s your delivery time?
5.Which payment methods are accepted?
6.How will you deliver my goods?
7.How do you inspect and guarantee your products?
8.What about after-sales service?
9.What are your main applications?
- Hydraulic systems
- Agricultural machinery
- Construction machinery
- Automobile industry
- Local distributors and maintenance centers
10.Can I get a discount for bulk orders?
Professional Manufacturer