WSM06020Y-01M-C-N-24DG | Hydac Solenoid Valve 350bar 40L/min
| Model Number | WSM06020Y-01M-C-N-24DG |
|---|
Product Description
Product Overview
The WSM06020Y-01M-C-N-24DG, WSM06020V-01M-C-N-24DG, and WSM06020Z-01M-C-N-24DG are core models in the HYDAC WSM06020 series of 2/2 solenoid directional valves, featuring metric cartridge construction compatible with the 06020 standard cavity. These valves are designed to control the start, stop, and direction of fluid flow in hydraulic systems for mobile and industrial applications.
Functional and Structural Differences:
WSM06020Y-01M-C-N-24DG: Pilot-operated poppet type, normally open. When de-energized, flow is permitted from port 2 to port 1; when energized, the valve closes. Maximum flow: 40 L/min.
WSM06020V-01M-C-N-24DG: Direct-acting poppet type, normally open. When de-energized, flow is permitted in both directions; when energized, flow is blocked in both directions. Maximum flow: 20 L/min.
WSM06020Z-01M-C-N-24DG: Pilot-operated poppet type, normally closed. When de-energized, flow is blocked; when energized, the valve opens.
Model Code Breakdown (using WSM06020Y-01M-C-N-24DG as an example):
WSM: Directional Seat Valve, metric
06020: Cavity designation (2-way cavity)
Y / V / Z: Function code (Y=pilot-operated normally open, V=direct-acting normally open, Z=pilot-operated normally closed)
01: Standard model
M: With manual override
C: Cartridge valve
N: NBR seals (standard)
24: 24V DC
DG: DIN connector per EN175301-803
As original HYDAC solenoid cartridge valves, these products offer complete interchangeability within the same series and cavity, requiring no modifications to manifold designs.
Technical Specifications
WSM06020Y-01M-C-N-24DG Specifications:
Model: WSM06020Y-01M-C-N-24DG
Brand: HYDAC
Product Type: 2/2 Solenoid Directional Valve
Valve Type: Pilot-Operated Poppet Type
Normal Position: Normally Open
Cavity: 06020
Maximum Operating Pressure: 350 bar (5075 psi)
Nominal Flow Rate: 40 L/min
Internal Leakage: Leakage-free, max. 5 drops/min (0.25 cm³/min) at 350 bar
Media Temperature Range: -20°C to +120°C
Ambient Temperature Range: -20°C to +60°C
Hydraulic Fluid: Hydraulic oil per DIN 51524 Parts 1, 2, and 3
Viscosity Range: 10–420 mm²/s
Coil Voltage: 24V DC
Current Draw (@ 20°C): 0.8 A
Voltage Tolerance: ±15%
Duty Rating: Continuous (100%), up to 115% rated voltage @ 60°C ambient
Response Time: Energized approx. 50 ms / De-energized approx. 35 ms
Recommended Filtration: ISO 4406 Class 21/19/16 or cleaner
Valve Body Material: High tensile steel
Seal Material: NBR (standard) / FKM (optional)
Weight: Valve complete 0.33 kg / Coil only 0.19 kg
WSM06020V-01M-C-N-24DG Specifications:
Model: WSM06020V-01M-C-N-24DG
Brand: HYDAC
Product Type: 2/2 Solenoid Directional Valve
Valve Type: Direct-Acting Poppet Type
Normal Position: Normally Open
Cavity: 06020
Maximum Operating Pressure: 350 bar
Nominal Flow Rate: 20 L/min
Internal Leakage: Leakage-free
Media Temperature Range: -20°C to +120°C
Ambient Temperature Range: -20°C to +60°C
Hydraulic Fluid: Hydraulic oil per DIN 51524 Parts 1 and 2
Viscosity Range: 10–420 mm²/s
Coil Voltage: 24V DC
Current Draw (@ 20°C): 0.8 A
Voltage Tolerance: ±15%
Duty Rating: Continuous (100%), up to 115% rated voltage @ 60°C ambient
Response Time: Energized approx. 40 ms / De-energized approx. 60 ms
Recommended Filtration: ISO 4406 Class 21/19/16 or cleaner
Valve Body Material: High tensile steel; hardened and ground components
Seal Material: NBR (standard) / FKM (optional)
Weight: Approx. 0.33 kg
WSM06020Z-01M-C-N-24DG Specifications:
Model: WSM06020Z-01M-C-N-24DG
Brand: HYDAC
Product Type: 2/2 Solenoid Directional Valve
Valve Type: Pilot-Operated Poppet Type
Normal Position: Normally Closed
Cavity: 06020
Maximum Operating Pressure: 350 bar
Nominal Flow Rate: 40 L/min
Key Technical Advantages
1. Wet-Type Solenoid Design for Quiet, Long-Life Operation
The WSM06020 series features an oil-immersed solenoid armature design—the movable iron core operates fully submerged in hydraulic oil. The hydraulic oil lubricates moving parts to reduce wear and cushions switching impact and vibration. This ensures extended service life and extremely low noise levels. Solenoid coils can be rotated 360° and replaced without opening the hydraulic system.
2. Hardened and Ground Control Elements for Superior Wear Resistance
Critical control elements such as poppets and seats are hardened and precision ground. The poppet-type seat valve design shuts off flow paths via a cone seat in the closed position, ensuring extremely low internal leakage (max. 5 drops/min).
3. Compact Cartridge Design for Space-Saving Installation
The metric cartridge construction enables direct installation in connection housings and control blocks for space-saving installation. The compact design significantly reduces external tubing and fittings, minimizing leakage risk and installation space requirements.
4. Superior Corrosion Resistance
All exposed surfaces are zinc-plated; WSM06020Y-01 features zinc-nickel coating that passes 1,000-hour salt spray testing for excellent corrosion resistance. Built-in coil seals effectively prevent moisture ingress into the solenoid system.
5. Flexible Electrical Connection and Voltage Options
Supports 24V DC supply (0.8 A current draw) with ±15% voltage tolerance. Equipped with DIN connector per EN175301-803. AC voltage can be rectified using a bridge rectifier built into the coil.
6. Integrated Manual Override
All models feature a manual override for emergency operation. In case of power failure or emergency, the spool can be manually actuated for emergency directional control, ensuring system safety.
Application Areas
WSM06020Y-01M-C-N-24DG (Pilot-Operated Normally Open, 40 L/min):
Construction Machinery — Hydraulic system control for excavators, loaders, and mobile equipment
Industrial Hydraulic Systems — Various high-flow normally open control applications
Presses and Forging Equipment — Safety and directional control for hydraulic systems
Injection Molding Machinery — On/off control for auxiliary oil circuits
WSM06020V-01M-C-N-24DG (Direct-Acting Normally Open, 20 L/min):
Machine Tool Hydraulics — Directional and on/off control for medium/low-flow actuators
Material Handling Equipment — Hydraulic control for forklifts and lifting platforms
Test Benches and Test Equipment — Hydraulic test circuits requiring fast response
Safety Interlock Devices — Safety control circuits that remain open when de-energized
WSM06020Z-01M-C-N-24DG (Pilot-Operated Normally Closed, 40 L/min):
Construction Machinery — Safety control systems requiring flow shut-off when de-energized
Industrial Automation — Safety shut-off and directional control for actuators
Hydraulic Power Units (HPU) — System unloading and pressure release control
Safety Interlock Devices — Safety protection circuits that automatically shut off when de-energized
Expert Maintenance Tips
1. Installation Guidelines
Thoroughly clean the cavity (06020 cavity) and valve exterior before installation to prevent foreign particles from entering and causing seal damage or spool sticking.
Installation torque: Coil lock nut torque 4 N·m, maximum 10.8 N·m.
No orientation restrictions—any installation orientation is acceptable based on manifold design requirements.
Cartridge valves can be installed directly in connection housings and control blocks without external piping.
2. Hydraulic Fluid Cleanliness
Recommended fluid cleanliness: ISO 4406 Class 21/19/16 or cleaner.
Use hydraulic oil meeting DIN 51524 Parts 1, 2, and 3.
Viscosity range: 10–420 mm²/s.
Media temperature range: -20°C to +120°C.
3. Electrical Connection Specifications
All models use 24V DC supply with current draw of 0.8 A (@ 20°C).
Voltage tolerance: ±15%.
Connector type: DIN EN 175301-803 standard.
Coils are rated for continuous duty (100%), capable of operating at 115% of nominal voltage at 60°C ambient.
Coils can be rotated 360° and replaced without opening the hydraulic system.
4. Reverse Flow Considerations (Pilot-Operated Normally Open)
WSM06020Y-01 allows free flow from port 2 to port 1 when de-energized. In the reverse direction (port 1 to port 2), flow is permitted when the hydraulic force on the spool exceeds the solenoid force (approx. 9–20 bar).
This reverse opening characteristic should be carefully considered during system design.
5. Periodic Maintenance Inspection
Inspect the valve body for external oil leakage every 2,000 operating hours or at least annually.
Check electrical connectors for looseness, oxidation, or moisture ingress.
Solenoid coils can be replaced quickly without opening the hydraulic system.
If response lag or unstable shifting is observed, first check system fluid cleanliness and spool seal condition.
For seal replacement: Standard NBR seals are suitable for -20°C to +100°C; FKM seals are optional for -20°C to +120°C.


Company Profile


Frequently Asked Questions
1.What ls our Main Products?
1.Hydraulic pump
2.Hydraulic valve
3.Hydraulic motor
4.Hydraulic cylinder
5.Hydraulic parts
2. What about the MOQ?
3.What are your advantages?
- Adhere to quality first.
- Support customization, ODM & OEM service.
- 1-year warranty and complete after-sales support.
- Safe and fast shipping worldwide.
- 24-hour online service for your inquiries.
4.Are you a manufacturer? What’s your delivery time?
5.Which payment methods are accepted?
6.How will you deliver my goods?
7.How do you inspect and guarantee your products?
8.What about after-sales service?
9.What are your main applications?
- Hydraulic systems
- Agricultural machinery
- Construction machinery
- Automobile industry
- Local distributors and maintenance centers