DG4V-3-2AL-M-U-H7-60 | Eaton Vickers Solenoid Valve 350bar 80L/min
| Model Number | DG4V-3-2AL-M-U-H7-60 |
|---|
Product Description
Product Overview
The DG4V-3-2AL-M-U-H7-60, DG4V-3-2AL-VM-U-D6-60, DG4V-3-0A-M-U-H7-60, and DG4V-3-2C-M-P7-H-7-56 are core models in the Eaton Vickers (now Danfoss Power Solutions) DG4V-3 series of direct-acting solenoid directional valves. The DG4V-3 series is Eaton Vickers’ most iconic NG6 size solenoid directional valve product line, with mounting pattern conforming to ISO 4401-03 / CETOP 3 / NFPA D03 standards. The series is renowned for its 350 bar (5,000 psi) high pressure, 80 L/min high flow, and wet-armature solenoid quiet operation technology.
DG4V-3-2AL-M-U-H7-60:
The DG4V-3-2AL-M-U-H7-60 is a 4-way, 2-position solenoid directional valve featuring spring offset configuration. The “AL” suffix denotes Left Hand Build—solenoid and switch locations are reversed compared to standard models. Single solenoid operation—when de-energized, the spool returns to the initial position by spring force. Features 24V DC supply (H7 coil code) with DIN 43650 electrical connector.
DG4V-3-2AL-VM-U-D6-60:
The DG4V-3-2AL-VM-U-D6-60 is also a 4-way, 2-position solenoid directional valve featuring spring offset configuration with Left Hand Build. Key differences from the H7-60 model: the VM suffix denotes Water Resistant Manual Override; the D6 coil code indicates 220/240V AC 50/60Hz supply. This configuration is particularly suitable for demanding wet or dusty environments.
DG4V-3-0A-M-U-H7-60:
The DG4V-3-0A-M-U-H7-60 is a 4-way, 3-position solenoid directional valve featuring Type 0 spool — all ports open in neutral (Open Center) . Features spring offset configuration with single solenoid operation. 24V DC supply. The Type 0 open center allows the pump to unload directly to tank in neutral—ideal for fixed-displacement pump systems for energy savings.
DG4V-3-2C-M-P7-H-7-56:
The DG4V-3-2C-M-P7-H-7-56 is a 4-way, 3-position solenoid directional valve featuring 2C spool type — all ports fully closed in neutral (closed center). Features spring centered configuration with double solenoid operation. 24V DC supply (H7 coil code). The P7 suffix denotes manual override in both end cap and solenoid end (dual override).
The DG4V-3 series features wet-armature solenoid technology—the movable iron core operates fully submerged in hydraulic oil, providing lubrication and cushioning for quiet, long-life, high-reliability operation. The product has passed fatigue life and endurance testing exceeding 20 million cycles.
As original Eaton Vickers DG4V-3 series solenoid directional valves, these products offer complete interchangeability within the same series and size, requiring no modifications to mounting interfaces or piping layouts.
Technical Specifications
DG4V-3 Series Common Specifications:
Brand: EATON VICKERS / DANFOSS POWER SOLUTIONS
Series: DG4V-3 Series, 60 Design
Product Type: Direct-Acting Solenoid Directional Valve
Size: NG6 / CETOP 3 / NFPA D03
Mounting Standard: ISO 4401-03 / CETOP 3 / NFPA D03
Mounting Type: Subplate/Manifold Mounted
Maximum Operating Pressure P/A/B: 350 bar (5,000 psi)
Maximum Operating Pressure T: 210 bar (3,000 psi)
Maximum Flow Rate: 80 L/min (21 GPM)
Response Time (Energized): 28–45 ms
Protection Class: IP65 (with properly installed connector)
Seal Material: Buna-N (NBR) standard/ Viton optional
Compatible Fluids: Petroleum-based hydraulic oil
Operating Temperature Range: -20°C to +70°C
Recommended Cleanliness: ISO 4406 19/17/14
DG4V-3-2AL-M-U-H7-60 Specifications:
Model: DG4V-3-2AL-M-U-H7-60
Spool Configuration: 4-way, 2-position
Spring Arrangement: Spring Offset
Build: Left Hand Build
Solenoid Configuration: Single Solenoid
Spool Type: 2 (closed center, all ports blocked)
Coil Voltage: 24V DC
Power Consumption: 30 W
Coil Code: H7
Electrical Connection: ISO 4400 (DIN 43650)
Manual Override: Standard
Indicator Light: Not equipped
Design Series: 60 Series
Material Number: 02-394649
Weight: 1.7 kg (3.7 LB)
DG4V-3-2AL-VM-U-D6-60 Specifications:
Model: DG4V-3-2AL-VM-U-D6-60
Spool Configuration: 4-way, 2-position
Spring Arrangement: Spring Offset
Build: Left Hand Build
Solenoid Configuration: Single Solenoid
Spool Type: 2 (closed center, all ports blocked)
Coil Voltage: 220/240V AC 50/60Hz
Coil Code: D6
Electrical Connection: ISO 4400 (DIN 43650)
Manual Override: Water Resistant
Design Series: 60 Series
Weight: Approx. 1.7 kg
DG4V-3-0A-M-U-H7-60 Specifications:
Model: DG4V-3-0A-M-U-H7-60
Spool Configuration: 4-way, 3-position
Spring Arrangement: Spring Offset
Spool Type: 0 (Open Center — all ports open)
Solenoid Configuration: Single Solenoid
Coil Voltage: 24V DC
Power Consumption: 30 W
Coil Code: H7
Electrical Connection: ISO 4400 (DIN 43650)
Manual Override: Standard
Design Series: 60 Series
Material Number: 869575
Weight: 1.6 kg
DG4V-3-2C-M-P7-H-7-56 Specifications:
Model: DG4V-3-2C-M-P7-H-7-56
Spool Configuration: 4-way, 3-position
Spring Arrangement: Spring Centered
Spool Type: 2C (Closed Center — all ports blocked)
Solenoid Configuration: Double Solenoid
Coil Voltage: 24V DC
Power Consumption: 30 W
Coil Code: H7
Manual Override: P7 (dual — end cap + solenoid end)
T Port Rating: 7 = 210 bar
Design Series: 56 Series
Key Technical Advantages
1. Wet-Armature Solenoid Design for Quiet, Long-Life Operation
The DG4V-3 series features Eaton Vickers’ proven wet-armature solenoid technology—the movable iron core operates fully submerged in hydraulic oil, providing lubrication to reduce wear and cushioning against switching impact and vibration. Compared to dry-armature designs, the wet-type configuration delivers lower noise, longer service life, and higher reliability. Coils can be changed quickly and easily without leakage from the hydraulic system.
2. 350 bar High Pressure and 80 L/min High Flow in Compact NG6 Size
Delivers 350 bar (5,000 psi) peak operating pressure and 80 L/min (21 GPM) flow capacity in a compact NG6 valve body. Tank port allowable back pressure reaches 210 bar (3,000 psi) —placing it at the forefront of directional control valves in its class.
3. Extensive Spool Type and Configuration Options
The DG4V-3 series offers multiple spool types including 0, 2, 3, 6, 8, 31, 33 and spring configurations including spring offset and spring centered. The “AL” Left Hand Build provides flexibility for special layout requirements. “P7” dual manual override provides additional assurance for safety-critical applications. “VM” water-resistant manual override is suitable for wet/dusty environments.
4. Manual Override and IP65 Protection
DG4V-3-2AL-VM-U-D6-60 features Water Resistant Manual Override. DG4V-3-2C-M-P7-H-7-56 features dual manual override (end cap + solenoid end). All models support manual override for emergency directional control during power failure. IP65 protection is achieved with properly installed connector.
5. International Standard Compliance for Global Interchangeability
Mounting conforms to ISO 4401-03 / CETOP 3 / NFPA D03 international standards. The DG4V-3 series offers complete interchangeability with globally adopted NG6 interfaces. The 60 Design Series has been optimized for higher performance and extended service life.
6. Proven Durability and Reliability
The DG4V-3 series has passed fatigue life and endurance testing exceeding 20 million cycles. Optimized spool and bore manufacturing reduces internal leakage, lowers power losses, and increases system efficiency.
Application Areas
DG4V-3-2AL-M-U-H7-60 / DG4V-3-2AL-VM-U-D6-60 (4-way, 2-position, spring offset, LH):
CNC Machine Tools — Directional control for hydraulic actuators
Unloading Circuits — System unloading and pressure release control
Safety Interlock Devices — Control circuits that automatically return to a safe state when de-energized
Hydraulic Power Units (HPU) — Directional control and flow switching
Left-hand special layout requirements — When standard models cannot meet installation orientation
DG4V-3-0A-M-U-H7-60 (4-way, 3-position, Type 0 open center, spring offset):
Fixed-Displacement Pump Systems — Pump unloads directly to tank in neutral, minimizing standby heating
Metalworking Machine Tools — Directional control and system unloading for centralized hydraulic stations
Hydraulic Presses and Forging Equipment — Press control requiring complete neutral unloading
DG4V-3-2C-M-P7-H-7-56 (4-way, 3-position, 2C closed center, spring centered):
Injection Molding Machinery — Directional and positioning control for clamping, injection, and ejection cylinders
CNC Machine Tools — Precision worktable positioning and locking control
Hydraulic Presses and Forging Equipment — Press slide position holding and control
Die-Casting Machines — Directional and positioning control for high-pressure casting equipment
Industrial automation systems — Hydraulic actuator control requiring precision position holding
Expert Maintenance Tips
1. Installation Guidelines
Mounting surface must conform to ISO 4401-03 / CETOP 3 / NFPA D03 standards.
Use 4 M5 mounting bolts—refer to manufacturer specifications for tightening torque.
Thoroughly clean the mounting surface and all ports (P, A, B, T) before installation to prevent foreign particles from entering and causing spool sticking or seal damage.
Left Hand Build (LH) models (2AL) have solenoid and switch locations reversed compared to standard models. Confirm solenoid position matches system wiring orientation during installation.
2. Hydraulic Fluid Cleanliness
Recommended fluid cleanliness: ISO 4406 19/17/14 or better.
Compatible fluids: Petroleum-based hydraulic oil. For phosphate ester and other specialty fluids, select Viton (FKM) seal option.
Operating temperature range: -20°C to +70°C.
Install a return line filter with minimum 10 μm filtration rating.
3. Electrical Connection Specifications
DG4V-3-2AL-M-U-H7-60 and DG4V-3-0A-M-U-H7-60 use 24V DC supply with power consumption of 30 W.
DG4V-3-2AL-VM-U-D6-60 uses 220/240V AC 50/60Hz supply.
DG4V-3-2C-M-P7-H-7-56 uses 24V DC supply.
Electrical connector: ISO 4400 (DIN 43650) standard. Ensure the connector is fully locked to maintain IP65 protection.
Coils can be replaced without disturbing hydraulic connections.
4. Manual Override
DG4V-3-2AL-VM-U-D6-60 features Water Resistant Manual Override for wet or dusty environments.
DG4V-3-2C-M-P7-H-7-56 features dual manual override (end cap + solenoid end).
Manual operation is for emergency use only and is not recommended for continuous duty.
5. Periodic Maintenance Inspection
Inspect the valve body for external oil leakage every 2,000 operating hours or at least annually.
Check electrical connectors for looseness, oxidation, or moisture ingress.
If response lag or unstable shifting is observed, first check system fluid cleanliness and verify the spool is not sticking.
Wet-armature solenoid coils can be replaced quickly without disturbing hydraulic connections.


Company Profile


Frequently Asked Questions
1.What ls our Main Products?
1.Hydraulic pump
2.Hydraulic valve
3.Hydraulic motor
4.Hydraulic cylinder
5.Hydraulic parts
2. What about the MOQ?
3.What are your advantages?
- Adhere to quality first.
- Support customization, ODM & OEM service.
- 1-year warranty and complete after-sales support.
- Safe and fast shipping worldwide.
- 24-hour online service for your inquiries.
4.Are you a manufacturer? What’s your delivery time?
5.Which payment methods are accepted?
6.How will you deliver my goods?
7.How do you inspect and guarantee your products?
8.What about after-sales service?
9.What are your main applications?
- Hydraulic systems
- Agricultural machinery
- Construction machinery
- Automobile industry
- Local distributors and maintenance centers
10.Can I get a discount for bulk orders?
Professional Manufacturer