KCG-3-350D-Z-M-U-H1-10 KCG-3-100D-Z-M-U-H1-10 Eaton Proportional Relief Valve 350 bar
| Model Number | KCG-3-100D-Z-M-U-H1-10, KCG-3-350D-Z-M-U-HL1-10, KCG-3-350D-Z-M-U-H1-10 |
|---|
Product Description
Product Overview
⚠️ Brand Attribution Note: The KCG-3 series proportional relief valves were originally developed by Vickers, later acquired by Eaton, and are now manufactured and sold under Danfoss Power Solutions. Products sold under any of these brands are technically identical with 100% direct interchangeability.
The KCG-3 series electro-hydraulic proportional relief valves are single-stage proportional relief valves engineered by Vickers for industrial hydraulic systems. These are open-loop, single-stage valves designed to regulate hydraulic system pressure in proportion to an applied electrical input.
The KCG-3 can be used for direct pressure control in low-flow systems, or as a pilot stage for larger pressure control valves. The valve responds to variations in current supplied to its solenoid—increasing current raises the pressure setting, while decreasing current lowers it. KCG series valve design ensures low hysteresis and good repeatability.
This product range covers the following models:
KCG-3-350D-Z-M-U-H1-10: Pressure range 6–350 bar, NG6, 24V DC solenoid, no manual override, DIN 43650 connector
KCG-3-100D-Z-M-U-HL1-10: Pressure range 3–100 bar
KCG-3-100D-Z-M-U-H1-10: Pressure range 3–100 bar
Our complete range of KCG-3 proportional relief valves strictly adheres to OEM technical standards, achieving 100% direct interchangeability with original components. Every unit undergoes 100% simulated operating condition bench testing prior to shipment, ensuring performance parameters are fully consistent with genuine Vickers/Eaton/Danfoss products. Direct replacement significantly reduces equipment downtime and maintenance costs.
⚠️ Model Code Decoding:
KC = Proportional Pressure Relief Valve
G = Subplate Mounted
3 = ISO 4401-03 (NG6 / NFPA D03) mounting interface
350 / 100 = Maximum controlled pressure range (350 bar / 100 bar)
D = Design series (1* series)
Z = No manual override
M = Metric interface
U = DIN 43650 / ISO 4400 electrical connector
H1 = 24V DC solenoid coil
10 = Design number (10–19 series share identical mounting dimensions)
Technical Specifications
KCG-3 Series General Specifications (based on Eaton/Vickers technical data)
Product Series: Vickers/Eaton/Danfoss KCG-3 series proportional relief valve
Product Type: Electro-hydraulic proportional relief valve
Valve Type: Single-stage, pilot-operated
Maximum Operating Pressure: 350 bar (5075 psi)
Maximum Flow Rate: 5 L/min (1.3 US gpm)
Mounting Interface: ISO 4401-03 (NG6 / NFPA D03)
Coil Voltage: 24V DC
Coil Current: 1.6 A
Coil Resistance: 7.3 Ω
Electrical Connection: ISO 4400 / DIN 43650 connector (U-type)
Seal Material: Buna-N
Body Material: Ductile Iron
Operating Temperature Range: -20°C to +60°C
Ingress Protection: IP65
Mounting Type: Subplate mounted
Recommended Cleanliness: ISO 4406 Code 17/15/12
Weight: Approx. 1.73 kg (3.82 LB)
Model Pressure Range Overview
KCG-3-350D-Z-M-U-H1-10: Controlled pressure range 6–350 bar, max flow 5 L/min
KCG-3-100D-Z-M-U-H1-10: Controlled pressure range 3–100 bar, max flow 5 L/min
KCG-3-100D-Z-M-U-HL1-10: Controlled pressure range 3–100 bar, with HL1 configuration
Key Technical Advantages
1. Electro-Hydraulic Proportional Control for Stepless Pressure Regulation
The KCG-3 series regulates system pressure by varying the current supplied to the solenoid—increasing current raises the pressure setting, decreasing current lowers it. When paired with a Vickers PWM output stage proportional amplifier, it delivers high-precision stepless pressure control.
2. Low Hysteresis and High Repeatability for Consistent Control
KCG series valve design ensures low hysteresis and good repeatability. This makes the KCG-3 particularly suitable for automated pressure cycling applications in injection molding machines and presses.
3. Self-Bleeding Design for Simplified Installation and Consistent Performance
The KCG-3 features a self-bleeding design that simplifies installation and ensures consistent performance. When used as a pilot stage for larger relief or reducing valves, it delivers low minimum pressure combined with fast and stable step response.
4. Standardized Mounting Interface for 100% Interchangeability
The KCG-3 conforms to ISO 4401-03 (NG6 / NFPA D03) standard mounting interfaces. Valves of the same size across brands are physically and interface-wise identical, enabling 100% direct interchangeability without manifold modification or system adjustment.
5. Compact NG6 Design for Space-Saving Installation
The KCG-3 features NG6 (CETOP 3 / NFPA D03) size with compact footprint. With maximum flow of 5 L/min, it is ideal for direct pressure control in low-flow systems or as a pilot control stage for larger valves.
6. Rugged Industrial-Grade Design for Harsh Environments
The KCG-3 features a ductile iron body with Buna-N seals, operating temperature range -20°C to +60°C, and IP65 ingress protection. Suitable for machine tools, automated production lines, construction machinery, and other industrial applications.
7. 100% Simulated Operating Condition Testing
Every unit undergoes 100% simulated operating condition bench testing prior to shipment, ensuring consistent, stable performance at rated pressure and flow.
Application Areas
Injection Molding Machinery: Proportional pressure control and automated pressure cycling for injection molding and blow molding machines
Hydraulic Machine Tools: Stepless pressure regulation for CNC machines and machining centers
Pressure-Controlled Pumps: Pilot control stage for pressure-controlled pumps
Pilot Control of Large Relief/Reducing Valves: Low-flow pilot actuation of large pressure control valves
Low-Flow Hydraulic Systems: Direct pressure control applications
Automated Production Lines: General industrial proportional pressure control
Test Equipment: Precision pressure control for hydraulic test benches
Expert Maintenance Tips
1. Must Use a Dedicated Proportional Amplifier
The KCG-3 series proportional solenoid requires specific PWM current drive—PLC direct voltage output cannot drive the solenoid. A Vickers/Eaton/Danfoss dedicated proportional amplifier (PWM output stage with output current control) is required. Input signals are typically 0–10V or 4–20mA.
2. Verify Model and System Compatibility Prior to Installation
The KCG-3 series offers 100 bar and 350 bar pressure range options. Confirm that the pressure range code (350/100) covers system operating pressure. The 350 model offers 6–350 bar control range, while the 100 model offers 3–100 bar.
3. Mounting Interface and Bolt Torque
The KCG-3 conforms to ISO 4401-03 (NG6) standard mounting interfaces. Use a torque wrench to tighten mounting bolts diagonally to the values specified in technical manuals to prevent valve body distortion or leakage.
4. System Cleanliness Management
The KCG-3 is a precision proportional valve demanding adequate oil cleanliness. Recommended system cleanliness: ISO 4406 Code 17/15/12 or higher. Install high-precision filters (filtration rating ≤10μm) in the system return line and inspect filter elements regularly.
5. Electrical Connection Precautions
KCG-3 series solenoid requires 24V DC power supply, coil current 1.6 A, resistance 7.3 Ω
Electrical connector type: ISO 4400 / DIN 43650
Verify supply voltage matches coil specifications and observe correct polarity prior to wiring
6. System Commissioning and Calibration
During commissioning, start from low command signals and gradually increase, monitoring system pressure response for smooth operation
Input signal vs. output pressure exhibits a linear proportional relationship
Vickers/Eaton/Danfoss recommended proportional amplifiers are recommended for optimal performance
7. Periodic Functional Checks
Perform functional checks every 2,000 operating hours or annually: verify linearity between command signal and output pressure, response time testing, leakage inspection, and hysteresis/repeatability verification. If reduced control accuracy, sluggish response, or abnormal leakage is observed, arrange for servicing or replacement.
Related Models:
KBFDG4V-5-33C50N25-Z-M1-PE7-H7-11
5996168-001 KBFDG4V52C30NZM1PE7H711
02-352598 KBDG5V52C90NM1PE7H110
5996650-001 KBHDG5V82C375N250XM1PE7H411
02-412506 KBFDG5V52C95NXM1PC7H110
02-412506 KBFDG5V52C95NXM1PC7H110
5995977-001 KBFDG4V32C20NZM1PE7H711
5996185-001 KBFDG4V533C50N25ZM1PE7H711
02-332111 KDG5V533C80NTMUH110
02-139417 DG5V7Y2C3TMUH730
02-145960 DG5V76C2TMUH730
834AN00035A DG5V52A2TMUH710
02-412669 DG5V52ATMUH710
02-413335 DG5V72CTVMUH730
616961 DG4V533CJMUH620
638593 DG4V56CJVMUH620
638591 DG4V52AJVMUH620
616769 DG4V52AMUA620
459178 DG4V52BLMUA620
616772 DG4V52NJMUH620
859188 DG4V32AVMUH760
859164 DG4V32NVMUH760
529762 DG4V32AMUH760
859478 DG4V30BVMUH760
529760 DG4V32CMUH760
529764 DG4V32NMUH760
529760 DG4V32CMUH760
529764 DG4V32NMUH760
859478 DG4V30BVMUH760
871112 DG4V30CVMUH760
638538 DG3VP3103AVMUH10
02-323043 DG5V72NTMUH730
02-352986 DG5V752C2TMUH730
02-145960 DG5V76C2TMUH730
02-138247 DG5V72CTMUH730
02-344733 DG5V8H8CVMUH10
02-156650 KCG3L160DZMUHL110P15T10
02-157263 KCG3250DZMUHL110P15T10
02-135165 KDG4V3S2C19SMUH560KBF



Company Profile


Frequently Asked Questions
1.What ls our Main Products?
1.Hydraulic pump
2.Hydraulic valve
3.Hydraulic motor
4.Hydraulic cylinder
5.Hydraulic parts
2. What about the MOQ?
3.What are your advantages?
- Adhere to quality first.
- Support customization, ODM & OEM service.
- 1-year warranty and complete after-sales support.
- Safe and fast shipping worldwide.
- 24-hour online service for your inquiries.
4.Are you a manufacturer? What’s your delivery time?
5.Which payment methods are accepted?
6.How will you deliver my goods?
7.How do you inspect and guarantee your products?
8.What about after-sales service?
9.What are your main applications?
- Hydraulic systems
- Agricultural machinery
- Construction machinery
- Automobile industry
- Local distributors and maintenance centers
10.Can I get a discount for bulk orders?
Professional Manufacturer