The Sun Hydraulics RBAE-KEN is a two-port, pilot-stage, direct-acting relief cartridge designed for pilot-capacity pressure control applications.
The RBAE family uses the T-8A cavity, provides 10 L/min nominal capacity, and is rated for 350 bar maximum operating pressure. The RBAE-KEN configuration specifically combines K handknob adjustment, the E pressure range of 1.7–28 bar, and N Buna-N sealing.
The valve is primarily intended to act as a pilot stage for larger Sun pilot-operated hydraulic valves. Sun’s technical guidance explains that RBAE pilot relief cartridges can remotely control the pressure setting of larger relief, sequence and reducing valves.
The additional models in the original title represent different hydraulic functions:
- PPFB-LBN — pilot-operated pressure reducing/relieving valve
- CEBC-LHN — semi-restrictive LoadAdaptive counterbalance valve
- CVGV-XCN — 240 L/min vented pilot-to-open check valve
- CVIV-XCN — 480 L/min vented pilot-to-open check valve
- CBCGT-11A — CBCG-related counterbalance configuration requiring complete-code verification
They should therefore be treated as related Sun Hydraulics cartridge products rather than interchangeable versions of RBAE-KEN.
Technical Specifications
RBAE-KEN
- Model: RBAE-KEN
- Brand: Sun Hydraulics
- Valve Type: Two-port, pilot-stage, direct-acting relief cartridge
- Functional Role: Pilot-capacity pressure control
- Cavity: T-8A
- Series: P
- Nominal Capacity: 10 L/min (2.5 GPM)
- Maximum Operating Pressure: 350 bar (5000 psi)
- Adjustment Control: K — Handknob
- Adjustment Range: E — 1.7–28 bar (25–400 psi)
- Standard Factory Setting: 14 bar (200 psi) for the E range
- Seal: N — Buna-N
- Typical Response Time: 2 ms
- Maximum Leakage: 1 cc/min at 24 cSt
- Valve Hex: 22.2 mm / 7/8 in
- Installation Torque: 27–33 Nm
- Adjustment Screw Hex: 4 mm
- Locknut Hex: 15 mm
- Locknut Torque: 9–10 Nm
- Weight: approx. 0.13 kg
- Construction: Floating-style cartridge.
PPFB-LBN
- Model: PPFB-LBN
- Brand: Sun Hydraulics
- Valve Type: Pilot-operated pressure reducing/relieving valve
- Cavity: T-2A
- Series: 2
- Nominal Capacity: 80 L/min (20 GPM)
- Maximum Operating Pressure: 350 bar
- Control Pilot Flow: 0.16–0.25 L/min
- Adjustment: L — Standard Screw
- Adjustment Range: Five turns
- Valve Hex: 28.6 mm
- Installation Torque: 61–68 Nm
- Adjustment Screw Hex: 4 mm
- Locknut Torque: 9–10 Nm
- Function: Pressure reduction at Port 1 with full-flow relief from Port 1 to tank Port 3
- Port 3 Back Pressure: Directly additive at a 1:1 ratio; maximum Port 3 pressure 210 bar.
CEBC-LHN
- Model: CEBC-LHN
- Brand: Sun Hydraulics
- Valve Type: LoadAdaptive counterbalance valve
- Cavity: T-11A
- Pilot Ratio: 3:1
- Control: L — Standard Screw
- Seal: N — Buna-N
- Function: Load holding and controlled load release
- Characteristic: Semi-restrictive, LoadAdaptive
- Exact flow and pressure range: Not independently verified for the complete CEBC-LHN code from a current primary Sun document located.
CVGV-XCN
- Model: CVGV-XCN
- Brand: Sun Hydraulics
- Valve Type: Vented pilot-to-open check valve
- Cavity: T-23A
- Series: 3
- Nominal Capacity: 240 L/min (60 GPM)
- Pilot Ratio: 3:1
- Maximum Operating Pressure: 350 bar
- Control: X — Standard Pilot
- Cracking Pressure: 2 bar
- Seal: Buna-N
- Valve Hex: 31.8 mm
- Installation Torque: 200–215 Nm
- Maximum Leakage: 0.07 cc/min at 24 cSt
- Weight: approx. 0.64 kg.
CVIV-XCN
- Model: CVIV-XCN
- Brand: Sun Hydraulics
- Valve Type: Vented pilot-to-open check valve
- Cavity: T-24A
- Series: 4
- Nominal Capacity: 480 L/min (120 GPM)
- Pilot Ratio: 3:1
- Maximum Operating Pressure: 350 bar
- Control: X — Standard Pilot
- Cracking Pressure: 2 bar
- Seal: Buna-N
- Valve Hex: 41.3 mm
- Installation Torque: 475–500 Nm
- Maximum Leakage: 0.07 cc/min at 24 cSt
- Weight: approx. 1.51 kg.
CBCGT-11A
- Model: CBCGT-11A
- Brand: Sun Hydraulics
- Product Family: CBCG counterbalance family
- Hydraulic Function: Load holding / overrunning-load control
- Pilot Ratio: CBCG family documentation identifies 4.5:1
- Maximum Operating Pressure: CBCG family documentation identifies 350 bar
- Exact suffix interpretation: Requires complete-code verification
- Exact flow, setting range and weight: Not stated as certified values without the exact primary model document
Key Technical Advantages
Fast 2 ms Pilot Response
The RBAE family has a typical response time of 2 ms, making RBAE-KEN suitable for fast pilot-pressure control applications where response speed is more important than high main-stage flow capacity.
Low-to-Medium Pilot Pressure Range
The E configuration provides a 1.7–28 bar adjustment range, making RBAE-KEN useful for lower-pressure pilot-control applications.
Handknob Adjustment
The K control identifies a handknob configuration, which is practical for applications requiring repeated field adjustment without using a hex key.
Combined Reducing and Relieving Function
PPFB-LBN combines pressure reduction and full-flow relief within one cartridge architecture. Its 80 L/min capacity makes it suitable for substantially higher-flow circuits than the RBAE-KEN pilot cartridge.
High-Capacity Pilot-to-Open Check Valves
CVGV-XCN and CVIV-XCN provide 240 L/min and 480 L/min capacity respectively, with 3:1 pilot ratio and 350 bar maximum operating pressure, supporting high-flow load-holding systems.
Standardized Cartridge Architecture
The models span T-8A, T-2A, T-11A, T-23A and T-24A cavity platforms, allowing engineers to integrate pressure-control and load-control functions directly into hydraulic manifolds.
Floating-Style Construction
Sun’s floating-style cartridge construction is designed to reduce the risk of internal component binding caused by excessive installation torque and cavity/cartridge machining variation.
Application Areas
RBAE-KEN
- Pilot pressure-control circuits
- Remote relief-valve control
- Sequence-valve pilot circuits
- Reducing-valve pilot circuits
- Hydraulic power units
- Compact hydraulic manifolds
PPFB-LBN
- Hydraulic power units
- Secondary pressure-control circuits
- Pressure reducing circuits
- Industrial hydraulic manifolds
- Machine tools
- Mobile auxiliary hydraulic circuits
CEBC-LHN / CBCG
- Hydraulic cylinders
- Boom circuits
- Winches
- Hoists
- Lifting equipment
- Load-holding systems
- Controlled lowering circuits
CVGV-XCN / CVIV-XCN
- Heavy-duty cylinders
- Large hydraulic actuators
- Crane systems
- Lifting machinery
- High-flow mobile hydraulics
- Hydraulic locking circuits
- High-capacity manifolds
Expert Maintenance Tips
Verify the E Pressure Range on RBAE-KEN
The E position in RBAE-KEN identifies the 1.7–28 bar adjustment range. Do not substitute this configuration for a higher-pressure RBAE variant simply because the cavity is the same.
Distinguish K From L Adjustment
Within the RBAE family:
- K = Handknob
- L = Standard adjustment screw
- O = Panel-mount handknob
- Y = Tri-grip handknob
These configurations can have different field-adjustment requirements even when the hydraulic cavity is identical.
Maintain Clean Pilot Oil
Because RBAE-KEN operates as a pilot-stage pressure-control element, contamination can affect the small control passage and valve seat. Inspect pilot passages, seals, filtration and the adjustment mechanism during service.
Account for PPFB-LBN Tank-Port Pressure
PPFB-LBN tank-port pressure adds directly to the valve setting at a 1:1 ratio, and Port 3 should not exceed 210 bar. Return-line design must therefore account for back pressure.
Use the Correct CVGV/CVIV Installation Torque
- CVGV-XCN: 200–215 Nm
- CVIV-XCN: 475–500 Nm
These values are substantially different and must not be interchanged.
Keep the CVIV Vent Port Open
Sun’s vented pilot-to-open check documentation warns that the vent port should not be blocked, because seal weepage can eventually cause valve malfunction.
Analyze Counterbalance Stability
For CEBC-LHN/CBCG applications, investigate pilot ratio, load pressure, flow, valve setting and pilot-line damping whenever chatter or unstable lowering occurs. Changing the pressure setting alone may not solve a counterbalance instability problem.
Verify the Complete Model Code
Cartridge replacement should be based on:
Part Number → Cavity → Function → Pressure Range → Control → Seal
rather than on the first four letters of the model code.
Apply 100% Simulated Working-Condition Testing
For your replacement products, a suitable factory test should reproduce:
Hydraulic Source → Cartridge Valve → Pilot/Load Circuit → Actuator Load
and measure:
- Pressure response
- Flow response
- Pilot response
- Leakage
- Adjustment repeatability
- Load-release stability
- Repeated-cycle performance
- Thermal behavior
This provides a much stronger basis for in-place interchangeability than visual inspection or static dimensional checking alone.




Company Profile


Frequently Asked Questions
1.What ls our Main Products?
1.Hydraulic pump
2.Hydraulic valve
3.Hydraulic motor
4.Hydraulic cylinder
5.Hydraulic parts
2. What about the MOQ?
3.What are your advantages?
- Adhere to quality first.
- Support customization, ODM & OEM service.
- 1-year warranty and complete after-sales support.
- Safe and fast shipping worldwide.
- 24-hour online service for your inquiries.
4.Are you a manufacturer? What’s your delivery time?
5.Which payment methods are accepted?
6.How will you deliver my goods?
7.How do you inspect and guarantee your products?
8.What about after-sales service?
9.What are your main applications?
- Hydraulic systems
- Agricultural machinery
- Construction machinery
- Automobile industry
- Local distributors and maintenance centers
10.Can I get a discount for bulk orders?
Professional Manufacturer